KE8101 |
Single Phase Meter Test System |
Used for testing various single phase electric and mechanical meter, Number of meter position : 3-96 |
Highlight
2 Integrated / Separated aluminum alloystructure, light and reliable,flexible choices
2 The number of meter positions can bechosen from 3 - 96
2 Perfect alarming protective function, autoprotection of the short circuitof voltage,the open circuit of current, andoverload.
2 Full automatic, semi automatic and manualoperation available
2 Supporting bar code input, which increasethe efficiency of input
2 Simultaneous test of the energy meterswith same specification, different constants and different classes.
2 The test of open circuit for Neutralvoltage (optional)
2 Auto mark locking increases the efficiencyof test
2 Forward and reverse active energy /forward and reverse reactive energy error test
2 Creeping and starting test
2 Standard deviation, 24 hour variation test
2 Influencing quantity test of voltage,frequency, harmonic
2 Calibration and verification of energyconstant
2 Powerful computer management system, easyand user-friendly
2 Perfect database management makes thestorage, searching, and viewing ofthe data possible, and the data can beconverted and exported in other forms
2 Adopt multi-serial port system, realizingthe parallel communication of computer and the tested meters (optional)
Wiring Diagram
Main Specification
| KE8101-12 | KE8101-24 | KE8101-48 | KE8101-64 | KE8101-96 |
Number of meter position | 12 | 24 | 48 | 64 | 96 |
Accuracy | ±0.05% | ||||
Voltage output | |||||
Output range (P-N) | 24V – 300V | ||||
Output power of voltage | 250VA | 500VA | 1000VA | 1500VA | 2000VA |
Resolution | Better than ± 0.01% | ||||
Stability | Better than ± 0.02% / 150s | ||||
Load regulation rate | Better than ± 0.01% | ||||
Distortion factor | Better than ± 0.3% (linear resistance load) | ||||
Harmonics output | 2nd -21st free programmable | ||||
Current output | |||||
Output range | 1mA – 120A (or customized,Max. 230A) | 1mA – 120A | |||
Output power of current | 350VA | 750VA | 1500VA | 2000VA | 3000VA |
Resolution | Better than ± 0.01% | ||||
Stability | Better than ± 0.02% / 150s | ||||
Load regulation rate | Better than ± 0.01% | ||||
Distortion factor | Better than ± 0.3% (linear resistance load) | ||||
Harmonics output | 2nd -21st free programmable | ||||
Phase output | |||||
Output range | 0 -- 360° | ||||
Resolution | ± 0.01° | ||||
Frequency | |||||
Output range | 45Hz – 65Hz | ||||
Resolution | ± 0.01Hz | ||||
Operation condition | |||||
Power supply | 220V±10%,50/60Hz±2Hz | ||||
Temperature | -10°C -- +40°C | ||||
Humidity | 35% -- 85%RH |
Copyright © 2013-2015 Guangzhou Kingrise Enterprises Co., Ltd. All rights reserved. GuangDong ICP No.12078987